Appendix B – EMC Installation Guidelines
49
Ground Strap
(connect to TH1)
I/O Flat Cable
User provided
power from a
clean DC power
supply (use
twisted pair cable)
Remove
Paint
Remove paint
if mounting on
this surface
VM50
Programmable
I/O Cable
Limits Cable
Communications Cable
Triggers Cable
Drive Cable
Encoder Cable
Braided-screen
Cables
Figure 3. EMC Connections for OEM6250